Search
 

 
   
   
   
   
username
password
» Signup
» Forgot Password
 

09980 Coatings for Concrete & Masonry


Download PDF Version

1. PRODUCT NAME

RENUWALL® A300
Elastomeric Wall Coating

2. MANUFACTURER

NATIONAL COATINGS CORPORATION

1201 Calle Suerte Camarillo, CA 93012

Phone: 800-423-9557
FAX: 800-294-3866
www.nationalcoatings.com

3. PRODUCT DESCRIPTION

RenuWall A300 is a high performance, acrylic, elastomeric coating for above grade exterior walls. It provides superior weatherproofing and long-term durability, with excellent adhesion, elongation and toughness.

RenuWall provides outstanding resistance to weathering, temperature changes, ultraviolet radiation and mildew. It retains its bright color, long-term flexibility, and breathability for many years.

RenuWall moves with the expansion and contraction cycles of a building to keep hairline cracks well sealed. As shrinkage cracks occur in new stucco, RenuWall bridges these openings to maintain a water tight and attractive surface.

RenuWall exceeds stringent ASTM D6083 and AIA 9830 performance requirements for elastomeric waterproofing coatings.
BENEFITS:
  • Superior Weatherproofing
  • Outstanding Adhesion to:
      Masonry
      Stucco
      Block
      Poured Concrete
      Brick
      Exterior Grade Wood
  • Long-Term Durability
  • Excellent Resistance to Temperature Extremes and Dirt Pick-up
  • Prolonged Wall Life
  • Reduced Life Cycle Costs
  • Safe and Easy Use
  • Environmentally Friendly

4. TECHNICAL DATA

See table on reverse side.

5. INSTALLATION

  • May be applied by spray or heavy napped rollers.
  • All surfaces must be clean, dry, and free of dirt, grease, oil, or other contaminants that would interfere with proper adhesion. Further surface preparation is project specific. See Installation Guide Specifications or contact a National Coatings Technical Consultant.
  • Apply minimum of two separate coats of 1 gallon per 100 square feet per coat.
  • Apply at temperatures above 50ºF.
  • Apply only when weather conditions will permit drying before rain, dew or freezing temperatures.
  • Cool temperatures and high humidity retard drying and curing.
  • For application details see specific Installation Guide Specifications.

6. AVAILABILITY AND COST

RenuWall A300 may be purchased directly from National Coatings. For information call 800-423-557.

7. WARRANTY

Various warranties are available for RenuWall Weatherproofing Systems installed by approved applicators. Prior project approval is required.

8. MAINTENANCE

Periodic maintenance of RenuWall Weatherproofing Systems ensures extended performance and reduces life cycle costs.

9. TECHNICAL SERVICES

Additional information, product brochures and installation guide specifications are available. Customized application instructions are also available from a National Coatings Technical Consultant.

10. FILING SERVICES

Additional product information is available from National Coatings Corporation.


RENUWALL® A300

ASTM D6083/AIA 9830 Technical Data
Properties
ASTM D6083 Method
AIA 9830 Method
Requirement
Result
Initial Tensile Strength (psi) ASTM D2370   200 Minimum > 325
Initial
Elongation (%)
ASTM D2370   100 Minimum > 250
Initial
Elongation (%)
  ASTM D412, 77°F 280 Minimum > 290
Initial
Elongation (%)
  ASTM D412, 0°F 50 Minimum > 40
Adhesion to Concrete, Dry (pli) ASTM C794, D903   No Reference > 6.0
Adhesion to Concrete, Wet (pli) ASTM C794, D903   2 Minimum > 1.0
Wind Driven Rain Resistance   Fed Spec TT-C-555-B Pass Pass
Tear Resistance (lbf / in) ASTM D624   > 60 > 100
Shore A Hardness   ASTM D2240 No Reference > 75
5000 Hour
Accelerated Weathering
ASTM D4798   No Chalk,
Crack, Discolor
No Chalk, Crack, Discolor
Elongation After
Accelerated Weathering (%)
ASTM D2370   100 Minimum > 200
Low Temperature Flexibility   ASTM C711 Pass 1/8” Mandrel
@ -15°F
Pass
Low Temperature Flexibility After Accelerated Weathering ASTM D522   Pass 1/2” Mandrel
@ -15°F
Pass
Permeance (perms) ASTM D1653   50 Maximum < 20
Water Swelling (%) ASTM D471   20 Maximum < 10
Fungi Resistance ASTM G21   Zero Rating Zero Rating
Salt Spray, 500 Hours   ASTM B-117 No Effect No Effect
Volume Solids (%) ASTM D2697   > 50 53 ± 1
Weight Solids (%) ASTM D1644   > 60 67 ± 1
Viscosity (KU) ASTM D562   85-141 120 ± 10

RenuWall A300 is for industrial/commercial applications only.  These suggestions and data are based on information we believe to be reliable.  They are offered in good faith, but without guarantee, as conditions and methods of use are beyond our control.